Reliable
Quite simply, the most reliable standby power solution
you can buy! The Modular Power System (MPS), designed
and built by Generac Power Systems, is a powerful
combination of the industry's most reliable generators
and superior, state of the art onboard paralleling
technology. No other manufacturer can offer you 99.9999%
reliability in such a cost-effective system.
Because of the high cost of paralleling switchgear,
previous industry attempts to achieve this level of
reliability for systems under six megawatts were either
not possible, or were far too expensive. Generac's
patented PowerManager® control system eliminates
the need for switchgear and provides built-in paralleling
capabilities for multiple generators. That gives you
the advantages of redundancy, flexibility and scalability
in a modular system that costs less than a large,
single engine genset.
For many businesses, the financial cost of a lengthy
power outage would be prohibitive. MPS provides the
assurance that you’ll keep operating, regardless.
Generac’s Modular Power System is offered in
three fuel options – diesel, natural gas, or
bi-fuel. Bi-fuel extends run times and reduces operating
costs as well as on-site diesel storage.
Redundant
With multiple generators on call, redundancy is built
in. In many applications, the load requiring the highest
degree of reliability is only a percentage of the
total generation capacity. In these situations, the
Modular Power System automatically backs up the most
critical load with N + 1 to N + 9 redundancy. The
resulting gains in reliability for supporting the
critical load are significant.
Scalable
The Modular Power System is designed with scalability
in mind. Each module is designed to simply "plug
and play" with an existing MPS system, allowing
multiple generators to be added as needed.
Scalability has two distinct advantages:
Significantly reduces up-front capital cost –
system can be initially sized for current or near-term
power needs
Eliminates the need to estimate total power requirements
up-front –simply add modules for more power
as needed
Flexible:
Generac's MPS system is based upon an assortment
of proven and reliable modules that are paralleled
to match any power requirement from 300 to 6000 kilowatts.
Available MPS Modules:
| 150 kW natural
gas
200 kW natural gas
300 kW diesel
300 kW bi-fuel
375 kW diesel
375 kW bi-fuel
|
400 kW diesel
500 kW diesel
600 kW diesel
600 kW Gemini bi-fuel
750 kW Gemini diesel
750 kW Gemini bi-fuel |
By utilizing a multiple generator solution instead
of a large single
genset, much greater application flexibility is available.
Modules are:
Lighter - For ease of installation or improved load
distribution on rooftop applications
Smaller - For space constrained applications
Compatible - Any size modules can be combined to achieve
required capacity.
Serviceable
Modular Power System generators use high volume,
high reliability, mass-produced, over-the-road truck
engines. These prime movers are easily serviceable
by on-road technicians. Likewise, maintenance and
replacement parts are more readily available and much
less expensive than larger engine counterparts.
Modular Power System generators can reduce maintenance
costs:
• Lower Cost of Parts
• Parts are Commonly Available
• Easy to Handle Components and Fluid Quantities
• Large Population of Qualified Technicians
Generac is the single source supplier of the entire
Modular Power System and therefore warrants all the
elements in the system.
Available
Modular Power System generators use readily available
high volume engines. These units can typically ship
in much shorter lead times than
large specialized engines.
Economical
One look at the engine dollar cost per kilowatt at
different outputs will show why the multiple generator
concept works so well. The mass-produced truck engines
we use cost less due to economies of scale. Larger
engines that produce more than 600 kW are built in
far fewer numbers, making them more costly to manufacture.
This chart shows the relative dollar cost per kW for
diesel engine gensets, with our MPS engines falling
in the most cost-effective range from 300 - 600 kilowatts.
Power Management
Generac's exclusive PowerManager® System is the
state-of-the-art technology that operates the Modular
Power System. Through the use of our Digital Control
Platform (DCP) technology, PowerManager handles the
operation of individual gensets, the seamless paralleling
of multiple units, and effective management of up
to ten generators at one time. The DCP is designed
and engineered for durability, featuring hardened
circuitry in an aluminum casing that is impervious
to electrical and magnetic interference, as well as
the outside environment. It's robust, reliable, and
built to provide decades of dependable service. |
a
powerful combination of the industry's most reliable power generators and superior, state of the art onboard paralleling technology. Generators MPS
|
Through the use of our Digital Control Platform (DCP) technology, PowerManager
handles the operation of individual gensets, the seamless paralleling
of multiple units, and effective management of up to ten industrial power systems at
one time. |
3
Day Training Schedule
When:
Jan 15,16,17, 2008
Mar 11,12,13, 2008
May 13,14,15,2008
Jun 10,11,12, 2008
Sept 9,10,11, 2008
Oct 14,15,16, 2008
Time: 8am - 4:30pm
Where: Glendale, AZ Location
Click
for More Industrial Generator Training Information |
|